Hi-Output W-2.4-8.2 Wall VAD c/w 103dB(A) Sounder (shallow base)
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB.
- Provides ‘W-2.4-8.2’ light distribution when wall mounted (min 0.4 lux over a 2.4m x8.2m cuboid area).
- Impressive 103dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14.5mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C (Type A) rated.
Technical Specifications
Approvals/certifications | |
---|---|
Protocol/compatibility | Compatible with C-TEC's XFP/ZFP XP95/Discovery Addressable Fire Panels. |
Application/operation | |
VAD category & coverage | |
Flash rate & colour | |
Supply/operating voltage | |
Quiescent current | |
Nominal SPL (Sound Pressure Level) | |
Alarm current | |
Indicators | Polling (green LED) & Short Circuit Isolator Active (amber LED). |
Product dimensions (mm) | |
IP Rating | |
Weight | |
Operating conditions/temperature |
Documentation
Approval Certificates
LPCB Third Party Approval Certificate – CAST, Hush-Pro & XP95/Discovery Sounder/VADs to EN54-3/23/17 | 562.78 KB | Download |
EU CPR Certificate of Conformity – BF433A/CX/SR Hi-Output Sounder VAD Shallow (CoC) | 189.72 KB | Download |
EU Declaration of Conformity – XP95/Discovery Hi-Output Sounder VADs (DoC) | 164.00 KB | Download |
EU Declaration of Performance – XP95/Discovery Hi-Output Sounder VADs (DoP) | 190.66 KB | Download |
UKCA CPR Certificate of Conformity – BF433A/CX/SR Hi-Output Sounder VAD Shallow (CoC) | 194.86 KB | Download |
UKCA Declaration of Conformity – XP95/Discovery Hi-Output Sounder VADs (DoC) | 164.31 KB | Download |
UKCA Declaration of Performance – XP95/Discovery Hi-Output Sounder VADs (DoP) | 333.54 KB | Download |
BIM/CAD Drawings
BIM Drawing (REVIT)
This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our
marketing team at marketing@c-tec.co.uk
CAD Drawing (DWG)
This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our
marketing team at marketing@c-tec.co.uk
VAD coverage (with multiplication factors applied)
VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the BF433A/CX/SR increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.
Lux level in area requiring coverage | W-2.4-8.2 Wall Mounted Direct Viewing | W-2.4-8.2 Wall Mounted Indirect Viewing | W-4-4 Wall Mounted Direct Viewing | W-4-4 Wall Mounted Indirect Viewing |
000-101 lux | 12.5m H x 42.6m W | 4.3m H x 14.8m W | 20.8m H x 20.8m W | 7.2m H x 7.2m W |
101-200 lux | 10.6m H x 36.1m H | 4.1m H x 13.9m W | 17.6m H x 17.6m W | 6.8m H x 6.8m W |
201-300 lux | 7.7m H x 26.2m W | 3.4m H x 11.5m W | 12.8m H x 12.8m W | 5.6m H x 5.6m W |
301-400 lux | 5.5m H x 18.9m W | 2.9m H x 9.8m W | 9.2m H x 9.2m W | 4.8m H x 4.8m W |
401-500 lux | 4.3m H x 14.8m W | 2.4m H x 8.2m W | 7.2m H x 7.2m W | 4.0m H x 4.0m W |
501-600 lux | 3.1m H x 10.7m W | 2.1m H x 7.4m W | 5.2m H x 5.2m W | 3.6m H x 3.6m W |
601-700 lux | 2.4m H x 8.2m W | not applicable | 4.0m H x 4.0m W | 2.8m H x 2.8m W |
701-800 lux | not applicable | not applicable | 2.8m H x 2.8m W | not applicable |