CAST-PRO Duct Detector
- Looks for the presence of smoke in air moving through ductwork.
- Kit includes a CAST-PRO CP416 optical smoke detector and a CAST CA408 base supplied in a durable plastic housing c/w sockets for the required length of Venturi tubing (tubing available separately – see More Information tab below).
- Compatible with C-TEC’s ZFP and XFP CAST protocol addressable fire panels.
- Can be located horizontally or vertically on the top, bottom or side of a duct ideally well away from devices that could interfere with its operation (heating, cooling or humidity devices).
- Includes an onboard short circuit loop isolator.
- <1mA alarm current.
- 570uA typical quiescent current @ 40V DC.
- Approval to EN 54-27:2015 pending (certificates attached apply to the kit’s CP416 detector only).
More Information
ACCESSORIES:
- ST-2:Venturi tube (0.6m)
- ST-5: Venturi tube (1.5m)
- ST-EXTEND: Venturi tube extension (1.06m)
- HFU204: Rubber gasket
- UG-MB-75: Mounting bracket (for insulated/circular ducts)
- UG-COVER-75: IP67 Waterproof cover (for outdoors or cold attics)
Technical Specifications
| Compatibility | Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels. |
|---|---|
| Type | |
| Sensitivity | 2 Detection Modes (normal or high sensitivity, default is normal) |
| Supply wiring | |
| Supply/operating voltage | |
| Quiescent current | |
| Alarm current (Imax at Vmin) | <1mA. |
| Alarm current (Iavg at Vmin) | <1mA. |
| Sound pressure level (LAFmax) at Vmax at 1m | N/A. |
| VAD category & coverage | |
| Indicators | |
| Connections | |
| Product dimensions (mm) | |
| IP Rating | |
| Weight | |
| Operating conditions/temperature |
Documentation
| CPDUCT/OPT CAST-PRO Duct Detector Instructions – DFU4110020 | 707.82 KB | Download |
| Uniguard Installation Instructions – Uncontrolled Document | 7.87 MB | Download |
| CAST-PRO Brochure – DML0551600 | 92.00 KB | Download |
| CAST PRO Device Instructions – DFU4110010 | 260.78 KB | Download |
| CAST PRO Polar Diagrams – DFU4110050 | 280.79 KB | Download |
| ActiV & CAST Detector Maintenance Instructions – DFU0000410 | 115.81 KB | Download |
Approval Certificates
| KIWA Approval & EU CPR Certificates of Conformity – CAST-PRO range to EN54-3/5/7/17/23/29/31 (zip folder) | 300.83 KB | Download |
| KIWA Third Party Approval Certificate – XFP & ZFP CAST Fire Panels and CAST Devices to EN54-13 (Systems Approval) | 130.87 KB | Download |
| EU Declaration of Conformity – CAST-PRO Optical Smoke & Heat Detectors (DoC) | 124.04 KB | Download |
| EU Declaration of Performance – CAST-PRO Fire Detectors (DoP) | 180.20 KB | Download |
Detection Modes
The default detection mode for the CP416 is Mode 2. This is Normal Sensitivity Smoke (0.24dB/m; 5.4%). It can also be programmed to operate in Mode 1, which is High Sensitivity Smoke (0.1dB/m; 2.3%).