CAST-PRO CO Fire + Smoke + Heat Multisensor c/w Tone Sounder & O-C-1.9-4 Red VAD

Order code: CP411TVR Category:
  • Multiple functionality in a single device – CO fire, smoke & heat multisensor fire detection plus a 92db(A) tone Alarm sounder and an O-C-1.9-4 red VAD – detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
  • Certified to EN54-3, 5, 7, 17, 23, 29 & 31.
  • Compatible with C-TEC’s ZFP touchscreen-controlled CAST protocol addressable fire panel.
  • MASC™ (Miniature Advanced Smoke Detection Chamber) and AFFIRM™ algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
  • Drift compensation functionality.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Multiple detection modes and different sensitivities for different times of the day.
  • 13.2mA max. alarm current (max vol, VAD on).
  • 630uA typical quiescent current @ 22-40V DC.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

      

Documentation
CAST-PRO Brochure – DML0551600 92.00 KB Download
CAST PRO Device Instructions – DFU4110010 260.78 KB Download
CAST PRO Polar Diagrams – DFU4110010 280.79 KB Download
Approval Certificates
EU CPR Certificate of Conformity – CP411 range (heat/optical/COfire/tone/voice/VAD) 300.83 KB Download
EU Declaration of Performance – CAST-PRO Fire Detectors, Sounders & VADs (DoP) 204.18 KB Download
Tone List

Here is a list of the 32 tone options available on this product. Note that different tones can be assigned to different functions in our ZFP programming software, e.g. Tone 1 could be set as the Primary tone and Tone 7 could be set as the Secondary tone. (Note, Tone 0 = Sounder OFF).

1. C-TEC Evacuation Tone (UK)

Tone: 535Hz for 0.5s, 800Hz for 0.5s

2. Alert (ALL)

Tone: 825Hz, 1s on, 1s off

3. C-TEC Fast Warble (UK)

Tone: 800Hz for 0.25s, 645Hz for 0.25s

4. Medium Sweep (UK)

Tone: 800 – 970Hz at 1Hz

5. Dutch Slow Whoop (sweep) (NL)

Tone: 500-1200Hz for 3.5s, 0.5s off

6. DIN Tone (DE)

Tone: 1200Hz – 500Hz for 1s

7. Swedish Alternating Tone (SWE)

Tone: 660Hz, 150ms on, 150ms off

8. Swedish all clear (SWE)

Tone: 660Hz constant on

9. Swedish Local Warning (SWE)

Tone: 660Hz, 1.8s on, 1.8s off

10. Swedish Pre-mess (SWE)

Tone: 660Hz, 6.5s on, 13s off, 20s period

11. Swedish Turn Out (SWE)

Tone: 554Hz for 1s, 440Hz for 1s

12. Swedish tone (SWE)

Tone: 660Hz 0.5s on, 0.5s off

13. Evacuation Tone (Apollo Comparable) (UK)

Tone: 550Hz for 0.5s, 825Hz for 0.5s

14. Alternating (Hochiki/Fulleon Comparable) (UK)

Tone: 925Hz for 0.25s, 626Hz for 0.25s

15. French Fire Tone (FR)

Tone: 554Hz for 100ms/440Hz for 380ms to 420ms

16. Australian Alert Tone AS1670 (ISO7731) (AUS)

Tone: 420Hz 0.625s on/off

17. Australian Evacuation Tone AS1670 (AUS)

Tone: 500 – 1200Hz, 0.5s/0.5s off x 3/1.5s off

18. Aus (fast rise sweep) (AUS)

Tone: 3x(500-1200Hz for 0.5s), 0.25s off

19. NZ (slow rise sweep) (NZ)

Tone: 500-1200Hz for 3.75s, 0.25s off

20. US Temporal LF (ISO 8201) (USA)

Tone: 3x(970Hz, 0.5s on, 0.5 off), 1s off

21. US Temporal HF (ISO 8201) (USA)

Tone: 3x(2850Hz, 0.5s on, 0.5 off), 1s off

22. Simulated Bell (USA/General)

Tone: n/a

23. Singapore Alert Tone (SG)

Tone: 1kHz, 2kHz 0.5s alternating

24. PFEER Alert Tone (ALL)

Tone: 950Hz, 0.25s on, 0.25Hz off

25. PFEER Alert Tone (ALL)

Tone: 970Hz, 1s on, 1s off

26. ISO 8201 (ALL)

Tone: 970Hz, 0.5s on/0.5s off x 3/1.5s off

27. ISO 8201 (ALL)

Tone: 2850Hz, 0.5s on/0.5s off x 3/1.5s off

28. Misc Tone 1 (ALL)

Tone: 925Hz continuous

29. Misc Tone 2 (ALL)

Tone: 975Hz continuous

30. Misc Tone 3 (ALL)

Tone: 2850Hz continuous

31. Fast Sweep (ALL)

Tone: 2.5-2.85kHz at 9Hz

Detection Modes

The default detection mode for the CP411TVR is Mode 10. This is Normal Sensitivity Smoke (0.24dB/m; 5.4%) + A2 heat + CO to EN54-31 (with additional CO detection to EN54-26, EN54-30 and EN50291-Mimic*).

Full options are:-
Mode 1: High Sensitivity Smoke (0.1dB/m; 2.3%) – no heat; no CO.
Mode 2: Normal Sensitivity Smoke (0.24dB/m; 5.4%) – no heat; no CO.
Mode 3: Heat Only A1R – no smoke; no CO.
Mode 4: Heat Only A2 – no smoke; no CO.
Mode 5: Heat Only B – no smoke; no CO.
Mode 6: High Sensitivity Smoke (0.1dB/m; 2.3%) + A1R heat – no CO.
Mode 7: Normal Sensitivity Smoke (0.24dB/m; 5.4%) + A1R heat; no CO.
Mode 8: Normal Sensitivity Smoke (0.24dB/m; 5.4%) + A2 heat; no CO.
Mode 9: High Sensitivity Smoke (0.1dB/m; 2.3%) + A1R heat + CO to EN54-31 NT*
Mode 10: Normal Sensitivity Smoke (0.24dB/m; 5.4%) + A2 heat + CO to EN54-31 NT*
Mode 11: Low Sensitivity Smoke (2.5dB/m; 43.8%), no heat + CO to EN54-31 MT**
Mode 12: Normal Sensitivity Smoke (0.24dB/m; 5.4%) + A2 heat + CO to EN54-31 NT***

* In addition to detecting CO to EN54-31, modes 9 and 10 although not certified to them also detect CO to EN 54-26, EN 54-30 and EN 50291(Mimic).
** In addition to detecting CO to EN54-31, mode 11 although not certified to it also detects CO to EN 50291(Mimic).
*** In addition to detecting CO to EN54-31, mode 12 although not certified to them also detects CO to EN 54-26, EN 54-30, CO Toxicity and EN 50291(Mimic).

Video