CAST Addressable Multi-Message Lockdown Alert Panel

Order code: LAP2/CA Category:
  • A dedicated feature-rich multi-message lockdown/invacuation control panel designed to help venues meet the requirements of The Terrorism (Protection of Premises) Act 2025, also known as ‘Martyn’s Law’.
  • Fully monitored and battery backed.
  • Secure keyswitches allow authorised users to select a voice message appropriate to the situation such as an internal or external threat requiring a partial lockdown, a threat requiring a full lockdown or an event that requires a full building evacuation (other options available to special order).
  • Panel includes 2 CAST protocol loop drivers capable of powering multiple CAST multi-message lockdown voice sounders.
  • ENVISION Enabled – fully compatible with C-TEC’s Cloud based data management software allowing incidents to be monitored on or off site.
  • Designed for use in conjunction with our CAST lockdown alert voice sounders, lockdown alert voice sounder VADs and lockdown alert call points.

   

More Information

The Terrorism (Protection of Premises) Act 2025, or “Martyn’s Law”, means premises with a capacity of 200 or more are now legally required to prepare to have public protection measures in place, including lockdown plans, by April 2027.

Designed to improve protective security and organisational preparedness across the UK, Martyn’s Law means that those responsible for certain premises and events need to be better prepared and protected, ready to respond in the event of a terrorist attack or security incident.

Standard tier venues (with capacities for 200-799 people) need public protection procedures, including lockdown, communication, and evacuation/invacuation plans. Enhanced tier venues (with 800+ capacities) need the same but are additionally required to implement other specific measures such as monitoring the premises’ immediate vicinity.

C-TEC’s battery-backed and fully-monitored lockdown solutions have been designed to help schools, theatres, shopping centres and other commercial and public venues comply with the legislation.

How does a lockdown system work?

A lockdown system (sometimes known as an invacuation system) is typically used to direct people to a designated secure area within a building to avoid threats from, say, active shooters or bomb alerts. To do this they sound distinctive alarms and/or voice messages throughout the building that are different from a venue’s fire evacuation or burglar alarm tones to avoid confusion.

The exact operation of a lockdown system and the actions that need to be taken when a threat is detected will be dependent on the venue’s risk assessment and emergency plan.

As requirements will differ from site to site, C-TEC’s lockdown solutions are designed to be tailorable to a building’s specific needs. They comprise a range of special multi-message voice sounders with a selection of pre-recorded messages and blue-flashing beacons that can be easily added to our dedicated LAP2/CA lockdown-alert panel or any ZFP CAST-protocol addressable fire system.

Messages can be triggered either manually via a set of secure keyswitches or by activating one or more lockdown call points.

Lockdown voice messages

The following voice messages can be triggered by the LAP2/CA when used in conjunction with C-TEC’s CA446A/DW/LD lockdown sounders or CA446A/DW/LD lockdown sounder VADs:-

Message 1 (internal threat, full lockdown situation)

“This is a full lockdown alert. There is an immediate threat within the building. Please follow full lockdown procedure. Stay calm and stay alert for further instructions.”

Message 2 (internal threat, partial lockdown situation)

“This is a lockdown alert. There is a threat within the building. Please follow partial lockdown procedures. Stay calm and stay alert for further instructions.”

Message 3 (external threat, partial lockdown situation)

“This is a lockdown alert. There is a threat outside the building. Please follow partial lockdown procedure. Stay calm and stay alert for further instructions.”

Message 4 (full evacuation)

“Attention please. This is an emergency. Please leave the building by the nearest available exit.”

Message 5 (all clear, situation resolved)

“All clear, The emergency has been resolved. All clear. All clear. The emergency has been resolved. All clear.”

Alternative lockdown messages

Custom or coded voice messages can also be arranged by special order – contact our lockdown system support team at lockdown@c-tec.co.uk for more details.

 

Technical Specifications
Protocol/compatibility

Mains supply

Mains rated current

Internal power supply

Total output current limited to

Battery charge capacity

Quiescent current

Max battery size and type

No. of loop drivers

Max. loop output current

Max. loop length

Max. addressable devices per loop

No. of conventional sounder circuits

EOL resistor value

Max. sounder output current

Auxiliary relays

Other outputs

Auxiliary inputs

PC connection

Pager/DECT connection

Graphics interface/diagnostics connection

Network connection

Indicators

Controls

Connections

Expansion connections

Product dimensions (mm)

Construction & finish

IP Rating

Weight

Operating conditions/temperature

Documentation
Lockdown Alert Flyer 445.79 KB Download
Lockdown Alert LAP2/CA Panel Instructions – DFU4465020 105.74 KB Download
XFP & ZFP CAST Addressable Fire Alarm System Brochure – DML0540100 5.16 MB Download
ZFP CAST Fire Panel Engineer Manual – DFU5030000 8.64 MB Download
ZFP CAST Fire Panel Quick Start Installation Guide – DFU5030010 1.25 MB Download
ZFP CAST Fire Panel Quick Start User Guide – DFU5030060 613.09 KB Download
ZFP CAST Fire Panel User Manual & Log Book – DFU5030050 3.31 MB Download
App Note – Installing ZTOOL Drivers – DFU0000500 115.54 KB Download
Z41 Naming Template – uncontrolled document 599 KB Download
ZFP Zone Naming Template – uncontrolled document 623 KB Download
ZFP Keyswitch Naming Template – uncontrolled document 613 KB Download
Preview voice messages

The following lockdown voice messages are available via our CA446A/DR/LD voice sounder and CA447A/DR/LD voice sounder VAD.

Message 1 (full lockdown situation)

“This is a full lockdown alert. There is an immediate threat within the building. Please follow full lockdown procedure. Stay calm and stay alert for further instructions.”

Message 2 (internal threat, partial lockdown situation)

“This is a lockdown alert. There is a threat within the building. Please follow partial lockdown procedures. Stay calm and stay alert for further instructions.”

Message 3 (external threat, partial lockdown situation)

“This is a lockdown alert. There is a threat outside the building. Please follow partial lockdown procedure. Stay calm and stay alert for further instructions.”

Message 4 (full evacuation)

““Attention please. This is an emergency. Please leave the building by the nearest available exit”.”

Message 5 (all clear, threat over)

“All clear, The emergency has been resolved. All clear. All clear. The emergency has been resolved. All clear.”

Custom or coded voice messages can also be arranged by special order – contact our lockdown system support team at lockdown@c-tec.co.uk for more details.

Key Features

CAST PROTOCOL FEATURES

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ life safety system protocol. Conceived, designed and realised by C-TEC, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Its key features include:

• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address via our award-winning CAST-PRO devices.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Intrinsically EN54-13 compliant.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• Designed and manufactured in the UK.

LAP2/CA CONTROL PANEL FEATURES

• Based on our ZFP2/CA fire alarm panel which is third-party certified to EN54-2, 4 and EN54-13.
• Attractive 450 x 462 x 127mm cabinet.
• Up to 64 nodes network capacity (any mix of panels and compact controllers).
• Hi-integrity networking.
• Very flexible cause and effects.
• Wide range of Switch & Indicator modules.
• Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
• User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
• Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
• 10,000 programmable and indicatable detection zones.
• Up to 38 characters of custom text per loop device.
• Automatic daylight saving (BST/GMT) mode.
• 20,000+ event memory (filterable by fire, fault & date).
• Non-fire supervisory event functionality.
• Optional thermal printers.
• Well-designed cabinets with easily removable electronics chassis.
• 20-way heavy-duty brass earth bar as standard.
• 72-hour standby (+ 30 min alarm) in standard cabinets.
• Built-in loop status & current-reading.
• Powerful engineering and commissioning functions including SafeMode and DeviceManager.
• Attractive Compact Controllers.
• Wide range of flush-fit bezels and attractive glazed stainless steel frames
• Powerful and intuitive PC programming tools
• Wide range of supported languages