10-30 Zone Emergency Indicator Panel
- A range of 10 to 30 Zone Emergency Indicator Panels c/w 12V 400mA PSUs.
- Fully compatible with C-TEC’s entire range of 800 Series Call System components.
- Capable of indicating standard (constant tone) and emergency (intermittent tone) calls.
- 10, 20 or 30 zonal alarm LEDs (dependent on model purchased, see below for parts listing).
- Optional mute button.
- 2 volt-free relay contacts.
- Surface mounting.
- Connections for optional Repeater panels and sounders to increase call indication levels.
Technical Specifications
Mains supply | |
---|---|
Internal power supply | |
Quiescent current | |
Max battery size and type | |
Alarm current | Determined by the number/type of field devices connected to the indicator panel/system. |
Auxiliary relays | |
Indicators | |
Controls | |
Expansion connections | Connections provided for up to 10 repeater panels and 3 remote sounders. |
Call acknowledgement functionality | No. If required use an NC910 or NC920 10 or 20 Zone Call Controller instead. |
Product dimensions (mm) | |
Construction & finish | |
IP Rating | |
Weight | |
Operating conditions/temperature |
Documentation
BIM/CAD Drawings
Operation
OVERVIEW
NC812KE, NC822KE and NC832KE indicator panels are fully compatible with all 800 Series call points, ceiling pulls, infrared ceiling receivers, monitoring points, overdoor lights and remote sounders.
Depending on the devices wired to it, Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. An optional Mute button is also provided to allow the user to silence standard calls.
OPERATION
STANDARD CALLS: when triggered by a calling device, the indicator panel’s internal buzzer sounds continuously and the relevant zone indicator(s) illuminate steady.
Pressing the Indicator Panel’s Mute Button, if fitted, silences the Panel’s internal buzzer. However, if a new call (standard or emergency) is triggered anywhere on the system, the buzzer will resound.
EMERGENCY CALLS: when triggered by a calling device, the Indicator Panel’s internal buzzer pulses and the relevant zone indicator(s) flash. This level of call takes priority over standard calls and cannot be muted at the Panel. An emergency call can only be reset at the device from which it was triggered or via a reset point, wired on the same zone.
Part Numbers (Masters & Repeaters)
NC812KE | 10 Emergency Indicator Panel c/w 12V 400mA PSU and optional mute button. |
NC822KE | 20 Emergency Indicator Panel c/w 12V 400mA PSU and optional mute button. |
NC832KE | 30 Emergency Indicator Panel c/w 12V 400mA PSU and optional mute button. |
NC811KE | 10 Emergency Repeater Panel |
NC821KE | 20 Emergency Repeater Panel |
NC831KE | 30 Emergency Repeater Panel |