Four Zone Call Controller (requires NC930 12V 250mA PSU)
- An attractively-designed four zone call controller c/w mute and reset buttons.
- Fully compatible with C-TEC’s entire range of 800 Series Call System components.
- Capable of indicating standard (constant tone) and emergency (intermittent tone) calls.
- Requires a separate NC930 12V 250mA PSU.
- Includes four zonal alarm LEDs, RESET and MUTE buttons.
- Two open collector outputs (Emergency and Aux Out).
- Up to two NC944s can be connected to one NC930 PSU to create a mini-call system of up to 8 zones.
- Mounts on a standard 25mm UK double gang back box.
Technical Specifications
Mains supply | |
---|---|
Quiescent current | |
Max battery size and type | Optional NC941B battery back up kit available for use with the NC930 12V 250mA PSU. |
Alarm current | Determined by the number/type of field devices connected to the call controller/system. |
Open collector outputs | |
Indicators | |
Controls | |
Call acknowledgement functionality | No. If required use an NC910 or NC920 10 or 20 Zone Call Controller instead. |
Product dimensions (mm) | 146 W x 87 H x 21 D mm. Mounts on a standard 25mm UK double gang back box. |
Construction & finish | |
IP Rating | |
Weight | |
Operating conditions/temperature | |
Notes |
Documentation
Dimensions & Mounting Information
Product Dimensions: | 147 W x 87 H x 39 D mm. Mounts on a 25mm UK double gang back box. |
Operation
OVERVIEW
The NC944 Four Zone Call Controller is compatible with all 800 Series call points, ceiling pulls, infrared ceiling receivers, monitoring points, overdoor lights and remote sounders.
Depending on how the Controller is configured and the devices connected to it, Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons are also provided to allow the user to Reset or Mute standard calls, as detailed below.
OPERATION
STANDARD CALLS: when triggered by a calling device, the Controller’s internal buzzer sounds continuously and the relevant zone indicator(s) illuminate steady.
Pressing the Controller’s Reset Button, if enabled, cancels all standard calls.
Pressing the Controller’s Mute Button, if enabled, silences the Controller’s internal buzzer. However, if a new call (standard or emergency) is triggered anywhere on the system, the buzzer will resound.
EMERGENCY CALLS: when triggered by a calling device, the Controller’s internal buzzer pulses and the relevant zone indicator(s) flash. This level of call takes priority over standard calls and cannot be muted, accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point, wired on the same zone.