XFP 1 Loop 16 Zone Addressable Fire Panel (XP95/Discovery protocol)
C-TEC’s XFP single loop 16 zone addressable fire alarm panel offers high performance at a very competitive price.
LPCB certified to EN54 parts 2 & 4, it is supplied in an attractive flush or surface mountable plastic enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo’s XP95/Discovery protocol.
Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe’s best-selling entry-level addressable fire panels.
Packed full of engineering features – some of which are not available on more expensive alternatives (see feature list below) – the XFP501E/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.
More Information
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Technical Specifications
| Approvals/certifications | |
|---|---|
| Protocol/compatibility | |
| Mains supply | |
| Mains rated current | |
| Internal power supply | |
| Total output current limited to | |
| Quiescent current | |
| Max battery size and type | |
| No. of loop drivers | |
| Max. loop output current | |
| Max. loop length | |
| Max. addressable devices per loop | |
| No. of conventional sounder circuits | |
| EOL resistor value | |
| Max. sounder output current | |
| Auxiliary relays | |
| Other outputs | 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs | |
| PC connection | |
| Indicators | |
| Connections | |
| Expansion connections | |
| Product dimensions (mm) | |
| Construction & finish | |
| IP Rating | |
| Weight | |
| Operating conditions/temperature |
Documentation
Approval Certificates
| LPCB Third Party Approval Certificate – CFP, XFP & ZFP Fire Panels to EN54-2/4 | 1.19 MB | Download |
| EU CPR Certificate of Conformity – XFP501E/X Fire Panel (CoC) | 256.52 KB | Download |
| EU Declaration of Conformity – XFP XP95/Discovery & XFP Hochiki Fire Panels (DoC) | 204.81 KB | Download |
| EU Declaration of Performance – XFP XP95/Discovery Fire Panels (DoP) | 175.23 KB | Download |
| UKCA CPR Certificate of Conformity – XFP501E/X Fire Panel (CoC) | 195.28 KB | Download |
| UKCA Declaration of Conformity – XFP XP95/Discovery & XFP Hochiki Fire Panels (DoC) | 160.71 KB | Download |
| UKCA Declaration of Performance – XFP XP95/Discovery Fire Panels (DoP) | 340.79 KB | Download |
Dimensions & Mounting Information
| Product dimensions: | 380 W x 235 H x 96 D mm. |
| Hole required for flush mounting: | 367 W x 220 H x 75 D mm. No bezel required. |