CAST Hi-Output W-2.75-9 Wall VAD c/w 103dB(A) Sounder (shallow base)

Order code: CA433A/SR Category:
  • LPCB certified to EN54-3, 17 & 23 and Kiwa Telefication certified to EN54-13.
  • Provides ‘W-2.75-9’ rated light distribution. Also rated as a W-4-4 VAD.
  • Impressive 103B(A) sound output @ 1m.
  • Onboard short-circuit loop isolator.
  • 13.5mA typical alarm current (460µA typical quiescent current @ 27-40V DC (VAD lit, sounder on max).
  • Group addressing facility allows multiple devices to be operated simultaneously.
  • 4 selectable volume levels and 31 selectable tones.
  • IP21C (Type A) rated.

        

More Information

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase, its key features include:

• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address (integrated devices) – coming soon.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Intrinsically EN54-13 compliant.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• Designed and manufactured in the UK.

Documentation
XFP & ZFP CAST Addressable Fire Alarm System Brochure – DML05401005.16 MB Download
CAST Hi-Output Sounder VAD Instructions – DFU43050101.74 MB Download
CAST Hi-Output Sounder Polar Diagram – DFU4300009268.76 KB Download
VAD coverage (with multiplication factors applied)

VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the CA433A/SR increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.

W-2.75-9 Wall MountedW-2.75-9 Wall MountedW-4-4 Wall MountedW-4-4 Wall Mounted
Lux level in area requiring coverageDirect ViewingIndirect ViewingDirect ViewingIndirect Viewing
000-101 lux14.30m H x 46.80m W4.95m H x 16.2m W20.8m H x 20.8m W7.2m H x 7.2m W
101-200 lux12.10m H x 39.60m W4.67m H x 15.3m W17.6m H x 17.6m W6.8m H x 6.8m W
201-300 lux8.80m H x 28.80m W3.85m H x 12.6m W12.8m H x 12.8m W5.6m H x 5.6m W
301-400 lux6.32m H x 20.70m W3.30m H x 10.8m W9.2m H x 9.2m W4.8m H x 4.8m W
401-500 lux4.95m H x 14.40m W2.75m H x 9m W7.2m H x 7.2m W4.0m H x 4.0m W
501-600 lux3.57m H x 11.7m W2.47m H x 8.1m W5.2m H x 5.2m W3.6m H x 3.6m W
601-700 lux2.75m H x 9.0m W1.92m H x 6.3m W4.0m H x 4.0m W2.8m H x 2.8m W
701-800 lux1.90m H x 6.3W1.65m H x 5.4m W2.8m H x 2.8m Wnot applicable
Approval Certificates
LPCB Third Party Approval Certificate – CAST, Hush-Pro & XP95/Discovery Sounder/VADs to EN54-3/23/17562.78 KB Download
KIWA Third Party Approval Certificate – XFP & ZFP CAST Fire Panels and CAST Devices to EN54-13 (Systems Approval)130.87 KB Download
EU CPR Certificate of Conformity – CAST CA433A/SR Hi-Output Wall Sounder VAD Shallow (CoC)189.59 KB Download
EU Declaration of Conformity – CAST Hi-Output Sounder VADs (DoC)76.44 KB Download
EU Declaration of Performance – CAST Hi-Output Sounder VADs (DoP)194.24 KB Download
UKCA CPR Certificate of Conformity – CAST CA433A/SR Hi-Output Wall Sounder VAD Shallow (CoC)195.39 KB Download
UKCA Declaration of Conformity – CAST Hi-Output Sounder VADs (DoC)162.54 KB Download
UKCA Declaration of Performance – CAST Hi-Output Sounder VADs (DoP)367.09 KB Download
Tone List

Here is a list of the 32 tone options available on this product. Note that different tones can be assigned to different functions in our XFP or ZFP programming software, e.g. Tone 1 could be set as the Primary tone and Tone 7 could be set as the Secondary tone. (Note, Tone 0 = Sounder OFF).

1. C-TEC Evacuation Tone (UK)

Tone: 610Hz for 0.5s, 810Hz for 0.5s

2. Alert (ALL)

Tone: 825Hz, 1s on, 1s off

3. C-TEC Fast Warble (UK)

Tone: 810Hz for 0.25s, 610Hz for 0.25s

4. Medium Sweep (UK)

Tone: 800 – 970Hz at 1Hz

5. Dutch Slow Whoop (sweep) (NL)

Tone: 500-1200Hz for 3.5s, 0.5s off

6. DIN Tone (DE)

Tone: 1200Hz – 500Hz for 1s

7. Swedish Alternating Tone (SWE)

Tone: 660Hz, 150ms on, 150ms off

8. Swedish all clear (SWE)

Tone: 660Hz constant on

9. Swedish Local Warning (SWE)

Tone: 660Hz, 1.8s on, 1.8s off

10. Swedish Pre-mess (SWE)

Tone: 660Hz, 6.5s on, 13s off, 20s period

11. Swedish Turn Out (SWE)

Tone: 554Hz for 1s, 440Hz for 1s

12. Swedish tone (SWE)

Tone: 660Hz 0.5s on, 0.5s off

13. Evacuation Tone (Apollo Comparable) (UK)

Tone: 550Hz for 0.5s, 825Hz for 0.5s

14. Alternating (Hochiki/Fulleon Comparable) (UK)

Tone: 925Hz for 0.25s, 626Hz for 0.25s

15. French Fire Tone (FR)

Tone: 554Hz for 100ms/440Hz for 380ms to 420ms

16. Australian Alert Tone AS1670 (ISO7731) (AUS)

Tone: 420Hz 0.625s on/off

17. Australian Evacuation Tone AS1670 (AUS)

Tone: 500 – 1200Hz, 0.5s/0.5s off x 3/1.5s off

18. Aus (fast rise sweep) (AUS)

Tone: 3x(500-1200Hz for 0.5s), 0.25s off

19. NZ (slow rise sweep) (NZ)

Tone: 500-1200Hz for 3.75s, 0.25s off

20. US Temporal LF (ISO 8201) (USA)

Tone: 3x(970Hz, 0.5s on, 0.5 off), 1s off

21. US Temporal HF (ISO 8201) (USA)

Tone: 3x(2850Hz, 0.5s on, 0.5 off), 1s off

22. Simulated Bell (USA/General)

Tone: n/a

23. Singapore Alert Tone (SG)

Tone: 1kHz, 2kHz 0.5s alternating

24. PFEER Alert Tone (ALL)

Tone: 950Hz, 0.25s on, 0.25Hz off

25. PFEER Alert Tone (ALL)

Tone: 970Hz, 1s on, 1s off

26. ISO 8201 (ALL)

Tone: 970Hz, 0.5s on/0.5s off x 3/1.5s off

27. ISO 8201 (ALL)

Tone: 2850Hz, 0.5s on/0.5s off x 3/1.5s off

28. Misc Tone 1 (ALL)

Tone: 925Hz continuous

29. Misc Tone 2 (ALL)

Tone: 975Hz continuous

30. Misc Tone 3 (ALL)

Tone: 2850Hz continuous

31. Fast Sweep (ALL)

Tone: 2.5-2.85kHz at 9Hz